HIT Series

The branch joint is precision manufactured, nitrogen purged and pressure tested to 5.2 MPa. It’s built for the job, not simply the drawing.

“Engineered for the Branch.Engineered For Superior Flow.”

Every installer has been there. The drawing indicates the VRF branch pipe goes here but the beam or the duct or the wall says otherwise. That’s usually when a project stays on schedule or starts bleeding a day to field-made elbows and more brazing joints than anyone anticipated for. On this point the HIT Series was developed on. A configuration of Exact Bend that allows the refrigerant stream to run right through as opposed to the customary detour a standard Y or U type branch joint necessitates. There is less copper to cut, less brazing of joints, and the installer has less time fighting the building and more time finishing the project.

All this is for naught if the joint itself is not trustworthy. Each HIT Series unit is precision made, brazed under a nitrogen purge to assure that copper-oxide scale never forms inside the line, and hydrostatically pressure tested at 5.2 MPa before it leaves the factory. This is proof, not promise, that it holds. Each item has its own traceability marking so that any fitting may be traced back to its batch and QC record months or years after installation by a consultant or contractor. Quality NBR or fire-rated XLPE insulation, precision cut Like the best parts are always built, the HIT Series is built quietly, precisely and in a way that allows everyone else on site to move on to the next thing.

Product Features

Product Specification

Model Number Pipe Pipe A (ID) Pipe B (ID) Pipe C (ID) Reducers Number & Qty
Pi-102SNK Gas Side 15.88 (5/8) – 19.05 (3/4) – 22.22 (7/8) – 25.4 (1) 22.22 (7/8) – 19.05 (3/4) – 15.88 (5/8) – 12.70 (1/2) 19.05 (3/4) – 15.88 (5/8) – 15.88 (5/8) – 12.70 (1/2) 1 x 1 Nos
Liquid Side 9.52 (3/8) – 12.70 (1/2) 9.52 (3/8) – 6.35 (1/4) 9.52 (3/8) – 6.35 (1/4)
Pi-162SNK Gas Side 28.58 (1-1/8) – 25.4 (1) 22.22 (7/8) – 25.4 (1) – 28.58 (1-1/8) 22.22 (7/8) – 19.05 (3/4) – 15.88 (5/8) – 12.70 (1/2) 1 x 1 Nos, 2 x 1 Nos
Liquid Side 12.70 (1/2) 12.70 (1/2) – 9.52 (3/8) 12.70 (1/2) – 9.52 (3/8) – 6.35 (1/4)
Pi-242SNK Gas Side 28.58 (1-1/8)-25.4 (1) 22.22 (7/8) – 25.4 (1) – 28.58 (1-1/8) 22.22 (7/8) – 19.05 (3/4) – 15.88 (5/8) – 12.70 (1/2) 2 x 1 Nos, 2 x 1 Nos
Liquid Side 15.88 (5/8) 19.05 (3/4) – 15.88 (5/8) – 12.70 (1/2) – 9.52 (3/8) 15.88 (5/8) 12.70 (1/2) – 9.52 (3/8) – 6.35 (1/4)
Pi-302SNK Gas Side 38.1 (1-1/2)-31.75 (1-1/4) 31.75 (1-1/4)-38.1 (1-1/2) 28.58 (1-1/8) 1 x 1 Nos, 2 x 1 Nos, 3 x 1 Nos, 4 x 1 Nos
Liquid Side 19.05 (3/4) – 22.22 (7/8) 22.22 (7/8) 19.05 (3/4) – 15.88 (5/8) – 12.70 (1/2) – 9.52 (3/8) 19.05 (3/4) 15.88 (5/8) – 12.70 (1/2) – 9.52 (3/8) – 6.35 (1/4)

Reducer Number & Size

Reducers Number & Size
1 9.52 (3/8) ID 6.35 (1/4)
2 28.58 (1-1/8) OD X 25.4 (1) ID X 22.22 (7/8) ID X 19.05 (3/4) ID X 15.88 (5/8) ID – 12.70 (1/2) ID
3 31.75 (1-1/4) OD -28.58 (1-1/8) ID X 25.4 (1) ID X 22.22 (7/8) ID
4 38.1 (1-1/2) OD -34.93 (1-3/8) ID

Why 227 Enterprise

Refrigerant distribution is one of those things that no one recognizes when it’s right and no one forgives when it isn’t – which is why 227 Enterprise considers the HIT Series to be essential infrastructure, not a line item. Each unit is pressure tested , supplied with insulation, and designed to be installed without requiring a return visit. This is not a convenience, this is the difference between a project being completed on time and one that is not, on a commercial facility that is continuously running. And if defects do occur on site, precision manufacturing silently minimizes the likelihood of them occurring at all, so the project delays and callbacks that take into a contractor’s margin never get a start. HIT Series is the system 227 Enterprise for the job of only keep the system operating for consultants, contractors and HVAC specialists.

Our Testimonials

clients say great things about us

Product Faqs

How to choose the right HIT Series Y Branch?

Selecting the right HIT Series Y Branch is easy. 227 Enterprise’s HIT Series Y Branches are OEM compliant and have model numbers that match HIT VRF system standards. Just use the model number listed on your Single Line Diagram (SLD), project drawings or equipment schedule. Our tech experts can also help you choose the right model for your project.

Are the pressure checked on the HIT Series Y branches?

Yeah. Each 227 Enterprise HIT Series VRF Y Branch is hydrostatically pressure tested to 5.2 MPa (754 PSI) for leak-free performance, structural integrity and long-term reliability. Every unit goes through extensive quality checks pre-shipping.

Can the HIT Series VRF Y Branch be utilised in retrofit HVAC projects?

Yes. The 227 Enterprise HIT Series Y Branch is ideal for new installations and retrofit projects as long as the chosen model is compatible with the specifications of the current HIT VRF system. Dimensions are OEM compliant for proper installation and easy integration with existing refrigerant lines.

Why is the 227 Enterprise HIT Series Y Branch easier to install than the normal Y Branch?

The 227 Enterprise VRF HIT Series Y Branch is built with a special T-type fitting that gives it considerable installation advantages over standard Y and U branch connectors. The straight-through design reduces the need for additional elbows, C-bends, and field-fabricated piping to avoid beams, walls, and other site obstructions. This allows for speedier installation, less copper used, cheaper labour costs and a cleaner piping layout, making it the ideal choice for current VRF HVAC projects.

Cost of the 227 Enterprise HIT Series VRF Y Branch?

The price for the VRF HIT Series Y Branch will vary on the model number, pipe size, type of insulation, order quantity and current copper prices. Copper costs vary constantly therefore we provide custom quotes based on your project requirements. Send your BOQ or model data to 227 Enterprise Pvt. Ltd. for the latest price.

Related Products

360° View WhatsApp Brochure